AC Current
Range
600.0 A
Resolution
0.1 A
Accuracy
2 % ± 5 digits (48 – 62 Hz)
Crest Factor (50/60 Hz)
2.5 @ 600 A
AC Voltage
Range
600.0 V
Resolution
0.1 V
Accuracy
1.0 % ± 5 digits (48 – 62 Hz)
DC Voltage
Range
600.0 V
Resolution
0.1 V
Accuracy
1 % ± 5 digits
Resistance
Range
600.0 Ω/6000 Ω
Resolution
0.1 Ω/1 Ω
Accuracy
1 % ± 5 digits
Continuity Beeper
30 Ω
Capacitance
Range
10.0 – 100.0 μF / 1000 μF
Resolution
0.1 μF/1 μF
Accuracy
1.9 % ± 2 digits
Mechanical Specifications
Size (L x W x H)
232 mm x 85 mm x 45 mm
Weight
370 g
Environmental Specifications
Operating Temperature
-10 °C to +50 °C
Storage Temp
-40 °C to +60 °C
Operating Humidity
Non condensing (< 10 °C)
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude
3000 Meters
Storage Altitude
12,000 Meters
EMI, EMC
Meets All applicable requirements in EN61326-1:2006
Temperature Coefficients
Add 0.1 x specified accuracy For each degree C above 28 °C or beLow 18 °C
Safety Compliance
ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV
Pollution Degree 2
EN/IEC 61010-2-32:2002
EN/IEC 61010-031:2002/A1:2008
Batteries
2 AA, NEDA 15A, IEC LR6